| GOES NON-INDEXING TWINSPIN™ OPERATING INSTRUCTIONS |
There are two models of the GOES TwinSpin™. One is indexing and one is non-indexing. If you have a non-indexing
TwinSpin™ (TS-5222) , you can control it with a DMX signal. If you do not have a DMX signal, you can set the control to“standalone” and it will operate whenever the power is turned on. Either model requires a GAM power supply.
| DMX OPERATION (NON-INDEXING TWINSPIN™) |
The Non-Indexing TwinSpin™ can be operated by a DMX signal. The channel setting on the power supply should be
set to 1 for the mode switch, then the following channel switches can be set to the channel of your choice. For example,
if you are going to use channel 1 on your dimmer board, then the sequence setting will be 1-0-0-1. In this mode setting
your DMX signal will start the TwinSpin™. The Dowser, if used, will be on the next higher channel automatically
(channel 2). With this above setting, your selected channel will control the TwinSpin™ as follows:
Channel |
TwinSpin Effect |
0-25 % |
Indexing to position |
26-49 % |
Indexing to position with pattern rotation reversed |
50-75 % |
Speed of continued rotation |
76-100 % |
Speed of continued rotation with patterns reversed |
|
|
MODE AND CHANNEL SWITCHES LOCATED ON DUAL POWER SUPPLY

|
| NON-DMX OPERATION (NON-INDEXING TWINSPIN™) |
The mode and channel set switches can be set for automatic sequence of pattern rotation. The selected sequence
or continuous rotation will start when the unit is powered and it will stop when power is turned off.
Standalone Modes Mode Switch = 0, 5, 6, & 7. No DMX required. Power supply only.
These are preprogrammed effects with parameters that can be set by the control switches as follows:
| Mode |
Gobo 1 |
Gobo 2 |
X100 |
X10 |
X1 |
| 0 |
Clockwise |
Counterclockwise |
0 |
Set 0-99 for
Speed control |
| Counterclockwise |
Clockwise |
1 |
| Both patterns go at the same speed |
Standalone Modes Mode Switch = 0, 5, 6, & 7. No DMX required. Power supply only.
These are preprogrammed effects with parameters that can be set by the control switches as follows:
Mode |
Function |
X100 Switch |
X10 Switch |
X1 Switch |
5 |
Swinging PendulumSway Back and Forth
|
Gravity of the Pendulum |
Maximum Speed
of the Pendulum |
Speed of gobo
1 & 2 rotation |
6 |
Random Roll Forwards |
Time Taken per Cycle |
Dwell Time at
Change of Direction
(While Stopped) |
Speed of gobo
1 & 2 rotation |
6 |
Timed Roll Forwards and Backwards |
Time Taken per Cycle |
Dwell Time at
Change of Direction
(While Stopped) |
Speed of gobo
1 & 2 rotation |
The non-indexing model has all the same control functions as the indexing model except the non-indexing model
selects a random position as the home point of the index. The indexing model sets itself to a fixed home position
(so it knows its position). |